Product Introduction
The low-temperature centrifuge is widely used in various fields such as biology, medicine, agriculture, and chemical industry, lt is an instrument that utilizes centrifugal force to perform gravity-based fractionation of samples. The maximum speed of this machine is n=15000rpm, and the centrifugal force is RCF=21381xg. This low-temperature centrifuge ensures that the samples do not heat up during centrifugation, providing optimal protection for the samples.
Product Features
True low temperature, centrifuge without heating up
Truly protect samples, reduce RNA/protein degradation, and achieve better experimental results
1. Unsymmetrical balancing monitoring system: if the sample is unsymmetrically placed and unbalanced, the instrument will automatically stop centrifuging.
2. Compatible with various rotors: suitable for 1.5/2mL (standard), 5mL and 10mL centrifuge tubes.
Working Environment
|
Power Parameters |
200-240VAC, 50-60Hz, 700W; power voltage fluctuation does not exceed 10% of the rated power voltage. |
|
Room Temperature |
5℃-40℃ |
|
Relative Humidity |
Maximum 80% |
|
Operating Location |
Indoor use |
|
Altitude |
Up to 2000 meters |
Technical Parameters
|
Dimensions |
530×355×268 mm |
|
Weight |
45 kg |
|
Screen Size |
5 inches |
|
Temperature Control Accuracy |
±2℃ |
|
Operating Time |
1-99 minutes |
Operation Parameters
|
Operating Mode |
Continuous |
|
Time Setting |
1-99 min |
|
Balancing Monitoring |
Gyroscope |
|
Refrigeration system |
SECOP Compressor Cooling |
|
Temperature Range |
-20℃ - Room Temperature |
|
Temperature Efficiency |
Specimens at room temperature go in (centrifuge for 10 minutes) and come out at 4℃ |
|
Rotor Capacity |
[1.5mL / 2mLx24] [5mLX12] [10mLX6] |
|
Rotor Replacement |
Quick-change mode: Only requires a dedicated wrench for removal and installation |
|
Rotor Removal |
Can be removed as a whole without opening the lid, to prevent the dispersion of specimen gas molecules |
|
Specimen safety |
Equipped with multiple sealing rings to prevent dispersion contamination |
|
Interface Operation |
Full touch screen interface, can be operated with gloves |
|
Machine Safety |
Double lock mechanism, and equipped with manual door opening mechanism during power failure |
|
Status Indicator |
LED strip status indicator, displays real-time working status |
|
Software Functions |
[Quick cooling setting] [Real-time temperature monitoring] [User program memory (up to 10 sets)] [Real-time parameter adjustment] [Gyroscope balancing detection] [Real-time monitoring of motor overvoltage, undervoltage, blockage, and overheating, with alarms and automatic shutdown] |
Standard Adapter

(2 mL × 24)